|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Description: |
Benefits: |
Primer: |
|
|
Therma Flame is a flame |
. |
Cost effective way to provide a |
Recommended primer varies, |
|
spread treatment for any |
|
class" A" or "B" fire rating |
depending on the primer |
|
flat, interior, latex paint. |
. |
Use only with flat latex base |
specified for the coating Flame |
|
Therma Flame forms a bum- |
|
Paint. |
Guard will be added to. |
|
resistant surface that |
|
|
|
|
insulates the substrate from |
. |
Does not change the paint |
Application: |
|
the flame, thus slowing flame |
|
properties or the way the paint |
|
|
spread. Therma Flame is UL |
|
is applied |
To achieve a class "B" fire |
|
rated and is a cost-effective |
. |
Environmentally friendly and |
rating, add one 6 ounce |
|
flame spread treatment |
|
non-toxic |
package per gallon. |
|
additive, which is an |
|
|
|
|
approved treatment with a |
Specifications: |
To achieve a class" A" fire |
|
|
class" A" or "B" fire rating. |
rating, add two 6 ounce |
||
|
When used as directed, |
. |
Do not store below 10°F |
packages per gallon. |
|
Therma Flame satisfies local, |
. |
Do not apply to exterior |
|
|
state and national fire codes |
|
surfaces. Therma Flame is for |
The material can be mixed into |
|
for reducing the flame |
|
interior use ONLY. |
the coating by paint shakers or |
|
spread rate of combustible |
. |
Therma Flame is not water- |
by stirring. Therma Flame will |
|
interiors in structures such |
|
soluble. Must be added into |
start settling in the coating |
|
as schools, hospitals, nursing |
|
flat, latex paint to be efficient. |
after about 3 hours, so it is |
|
homes, daycare's, churches, |
. |
No special preparations or |
advised that the coating be |
|
private dwellings, and many |
mixed well before applying |
||
|
others. Once added to flat, |
|
delivery is needed, but good |
and every hour during |
|
interior, latex paint, Flame |
|
painting practices still apply |
application. |
|
Guard does not adversely |
|
(do not paint in the rain, use |
|
|
affect the color, spread |
|
appropriate ventilation, etc.) |
|
|
ability or curing time of the |
|
|
|
|
coating and may be applied |
|
|
|
|
via brush, roller and sprayer. |
|
|
KEEP FROM FREEZING |
|
Therma Flame, in no way, |
|
|
Do not apply when |
|
drastically affects the coating |
|
|
temperatures are below 50°F. |
|
to which it is added. The |
|
|
Coatings should only be |
|
color, spread ability, curing |
|
|
applied when ventilation is |
|
time, texture, sheen and |
|
|
adequate. |
|
luster remain the same. |
|
|
|
|
When dried, Therma Flame |
|
|
|
|
additive is completely |
|
|
|
|
undetectable. |
|
|
|
![]() |
|